Auto Relay FLS860

Short Description:

●150A switching capability

●Terminal limit continuous current 180A

● Stability of base structure            

● Dust cover IP6K5

●Outline dimensions: 98 *71*40


Product Detail

Product Tags

Features

150A switching capability

Terminal limit continuous current 180A

Stability of base structure            

Dust cover IP6K5

Outline dimensions: 98 *71*40

Specification

Contact data

Limited break current 300A     Minimum:1000mA  @ 5DVC

Contact form

1 from A(NO  bridge connection)

Contact material

AgSnO2

Max,Operating Current

150A

Coil data

141Ω±10% resistor

35Ω±10% resistor

Rated voltage of coil

24VDC

12VDC

Rated coil power

4.1W

4.1W

The pull in voltage

≤17VDC

≤8VDC

Release voltage

≥2.4VDC

≥1.2VDC

Operating time

<30mS

<30mS

Release time

<15mS 5

<15mS

Dielectric  withstanding  voltage         Electrical life

5 X105

   Mechanical life

1 X107

         Life       Between coil contacts

500VAC 1min

       Mechanical life

1 X107

Ambient temperature

-40℃~+85℃

Protection category

IP6K5

Terminal type  

Insert(coil)

Screw terminals(load)

Installation method  

Flange mounting

ORDERING  GUIDE

FLS860
860
EXTERNAL DIMENSIONS

            

Remark: (1)In case of no tolerance shown in outline dimension: outline dimension≤1mm, tolerance should be ±0.2mm;

Outline dimension>1mm and≤5mm, tolerance should be ±0.3mm; outline dimension>5mm,

tolerance should be ±0.4mm.

 

The wiring diagram  

8601


  • Previous:
  • Next:

  • Related Products

    WhatsApp Online Chat !