12V 24V 20A 30A 40A Auto Relays for Heavy Truck Car
Features:
● A set of bridge contact points
● 150A switching capability
● plastic sealed
● Outline dimensions: 33.5X52.4X65
● Working temperature as high as 75 °C
Specification
Contact Form | 1 A One set of bridge |
Maximum continuous | 150A |
Max.Operating Voltage | 110VDC |
Electrical durability | 5×104times |
Mechanical Durability | 1×107times 300 times/minute |
Insulation Resistance | 20MΩ |
Operate/Release | 50ms or less |
Release Time | 50ms or less |
Operating temperature | -40℃~+75℃ |
Vibration | 10Hz~500Hz,5.0G |
Package mode | Plastic seal |
Contact parameter
Contact load voltage | Load type | Contact load voltage A | On-off ratio | Electrical durability | Contact material | Test environment temperature | Contact wiring diagram | ||
bridging(1A) | Turn on S | Turn off S | |||||||
14VDC | Resistive | Turn on | 150 | 1 | 4 | 5×104次 | Agsno2In2o3 | 23℃ | see picture 1 |
Turn off | 150 | 1 | 4 | 5×104次 | Agsno2In2o3 | 23℃ | see picture 1 | ||
28VDC | Resistive | Turn on | 100 | 1 | 4 | 5×104次 | Agsno2In2o3 | 23℃ | see picture 1 |
Turn off | 100 | 1 | 4 | 5×104次 | Agsno2In2o3 | 23℃ | see picture 1 | ||
72VDC | Resistive | Turn on | 50 | 1 | 4 | 5×104次 | Agsno2In2o3 | 23℃ | see picture 1 |
Turn off | 50 | 1 | 4 | 5×104次 | Agsno2In2o3 | 23℃ | see picture 1 | ||
110VDC | Resistive | Turn on | 30 | 1 | 4 | 5×104次 | Agsno2In2o3 | 23℃ | see picture 1 |
Turn off | 30 | 1 | 4 | 5×104次 | Agsno2In2o3 | 23℃ | see picture 1 |
Coil Ratings
Standard | Normal voltage (VDC) | Pick-up voltage (VDC) | Drop-out voltage (VDC) | Coil resistace (Q±10%) | Parallel resistance (Q±5%) | Equivalent resistance (Q±10%) | Power consumption (W) | Max.allowable overdrive voltage1) (VDC) | |
20 °C | 85 °C | ||||||||
12 | 8.4 | 1.2 | 90 | - | - | 1.6 | 20.2 | 15.7 | |
12 | 8.4 | 1.2 | 80 | 680 | 79.5 | 1.8 | 20.2 | 15.7 | |
24 | 16.8 | 2.4 | 360 | - | - | 1.6 | 40.5 | 31.5 | |
24 | 16.8 | 2.4 | 320 | 2700 | 317.6 | 1.8 | 40.5 | 31.5 |