Auto Relay FLS821-6

Short Description:

30A switching capability

1 form Acontact form

 Outline dimensions: 28.0 X23.0X29.5


Product Detail

Product Tags

Features

 30A switching capability

 1 form A contact form

 Outline dimensions: 28.0 X23.0X29.5

Specification

Contact Form 1A
Contact Material    AgSno2
Max,Operating Current 30A
Max.Operating Voltage 27VDC
Rated Load(Resistive load) 1A:30A 13.5VDC 15A 27VDC
Insulation Resistance 100MΩ
Dielectric Strength(Coil and Contact) 500VAC
Ambient Temperature -40°C~+85°C
Operate/Release Time 10ms/10ms
Mechanical Llife(min) 1 X106
Electrical Life(min) 1 X105
Terminal Type Terminal

Coil Ratings

Standard

     

Normal voltage

(VDC)

Pick-up voltage

(VDC)

Drop-out voltage

(VDC)

Coil resistace

 (Q±10%)

Parallel resistance

(Q±5%)

Equivalent

resistance

(Q±10%)

   Power

consumption

(W)

Max.allowable overdrive voltage1) (VDC)

             

20 °C

85 °C

12

8.4

1.2

90

-

-

1.6

20.2

15.7

12

8.4

1.2

80

680

79.5

1.8

20.2

15.7

24

16.8

2.4

360

-

-

1.6

40.5

31.5

24

16.8

2.4

320

2700

317.6

1.8

40.5

31.5

ORDERING  GUIDE

 FLS821

EXTERNAL DIMENSIONS

C

Remark: (1)In case of no tolerance shown in outline dimension: outline dimension≤1mm, tolerance should be ±0.2mm;

Outline dimension>1mm and≤5mm, tolerance should be ±0.3mm; outline dimension>5mm,

tolerance should be ±0.4mm.

 

C1